1 Purpose
1.1 This Safety Guideline is intended as a set of performance-based environmental, health, and safety (EHS)
considerations for semiconductor manufacturing equipment. 2 Scope
2.1 Applicability — This Safety Guideline applies to equipment used to manufacture, measure, assemble, and test
semiconductor products.
2.2 Precedence of Sectional Requirements — In the case of conflict between provisions in different sections of this
Safety Guideline, the section or subsection specifically addressing the technical issue takes precedence over the more
general section or subsection. 3 Limitations
3.1 This Safety Guideline is intended for use by supplier and user as a reference for EHS considerations. It is not
intended to be used to verify compliance with local regulatory requirements.
3.2 It is not the philosophy of this Safety Guideline to provide all of the detailed EHS design criteria that may be
applied to semiconductor manufacturing equipment. This Safety Guideline provides industry-specific criteria, and
refers to some of the many international codes, regulations, standards, and specifications that should be considered
when designing semiconductor manufacturing equipment.
3.3 This Safety Guideline is not intended to be applied retroactively.
3.3.1 Equipment models with redesigns that significantly affect the EHS aspects of the equipment should conform to
the latest version of SEMI S2.
3.3.2 Models and subsystems that have been assessed to a previous version of SEMI S2 should continue to meet the
previous version, or meet a more recently published version, and are not intended to be subject to the provisions of
this version.
3.4 In many cases, references to standards have been incorporated into this Safety Guideline. These references do not
imply applicability of the entire standards, but only of the sections referenced.
S6 Exhaust Ventilation 排气通风
1 Purpose
1.1 This Safety Guideline provides safety performance criteria for exhaust ventilation of semiconductor manufacturing equipment (SME) and test methods for assessing conformance to those criteria.
1.2 The optimization of exhaust ventilation is becoming more important as energy efficiency and the physical constraints of exhaust ventilation utilities in user facilities become more pronounced. Efficiently designed exhaust ventilation should be provided to protect personnel, property, and the environment from health and safety risks. The purpose of this Safety Guideline is to provide performance and design principles and test methods and criteria for exhaust ventilation. 2 Scope
2.1 This Safety Guideline applies to semiconductor manufacturing equipment that incorporates exhaust ventilation intended to be connected to user facilities’ exhaust ventilation system(s).
2.2 The criteria of this Document should be applied to exhaust ventilation systems provided for the purposes (in whole or in part) of personnel protection, equipment protection, and fire risk reduction.
2.3 The performance and assessment criteria in this Document apply to all of the equipment provided by a supplier to a user or to another supplier to be provided as part of equipment the latter supplier provides to a user.
2.4 This Document is intended to help the semiconductor equipment supplier design equipment exhaust ventilation systems to a common set of performance criteria as well as to provide assistance to both users and suppliers in the understanding of exhaust ventilation requirements for equipment systems. It is not intended to establish design
specifications.
2.5 Test methods are provided in § 8 and several appendices.
2.6 This Document is not intended to limit hazard evaluation methods or control strategies (e.g., design principles) employed by suppliers or users. Many different methods may be employed if they provide a sufficient level of protection. 3 Limitations
3.1 This Document does not provide criteria for determining whether exhaust ventilation is to be used to mitigate the risks of the use of a substance within SME. It provides criteria for exhaust ventilation features of SME when exhaust ventilation has been selected as a means of mitigating such risks.
3.2 Effluent sampling for environmental criteria is not covered in this Document. Mass balance sampling for
environmental characterization is not covered in this Document.
3.3 Ventilation for particle control for product quality (i.e., other than for safety) is outside the scope of this Safety Guideline.
3.4 Ventilation for control of smoke is outside the scope of this Safety Guideline.
3.5 Ventilation for removal of heat is outside the scope of this Safety Guideline.
3.6 This Document is written with the assumption that the users’ exhaust ventilation distribution systems will be designed with central fans, ducting, and, where applicable, abatement equipment. Suppliers should be aware that other types of exhaust ventilation systems may be encountered. End users should communicate relevant details of their exhaust ventilation systems to their suppliers, particularly if the systems deviate from the assumed model.
3.7 This Safety Guideline is not intended to be applied retroactively.
3.7.1 Equipment models with redesigns or other changes (such as process changes) that significantly affect the
equipment ventilation, air flow or risks being controlled by these features should conform to the latest version of SEMI S6.
3.7.2 Models and subsystems that have been assessed to a previous version of SEMI S6 should continue to meet the previous version, or meet a more recently published version, and are not intended to be subject to the provisions of this version.
S8 Ergonomics Engineering人机工程安全
1 Purpose
1.1 These Safety Guidelines provide ergonomics design principles and considerations for semiconductor manufacturing equipment.
1.2 The purpose of these Safety Guidelines is to promote compatibility between the user and the equipment in the manufacturing environment. The following general principles are integral to the ergonomics design and evaluation of equipment:
1.2.1 The equipment should be designed to optimize safety by distributing tasks. Tasks should be distributed among hardware, software, and users to make the best use of their respective capabilities and to minimize limitations and hazards. Appropriate distribution of tasks will also optimize performance.
1.2.2 Equipment should be designed to minimize potential for errors and mishaps, by conforming to users’ expectations.
1.2.3 The equipment design should reduce fatigue and injury by fitting the equipment to the expected body size, strength, and range of motion characteristics of the user population. Such design will also facilitate task performance. 2 Scope
2.1 The guidelines address safety aspects of ergonomics engineering in the design of semiconductor manufacturing equipment. It should be noted that in order to ensure comprehensive coverage of potential safety hazards, some guidelines also address general design goals for effective human-machine performance. The guidelines apply to the design, operation, maintenance, and service of semiconductor manufacturing equipment, as well as, to a limited extent, equipment installation. 3 Limitations
3.1 International, national, and local standards, codes, and regulations must be consulted to ensure that equipment meets regulatory requirements.
3.2 Human factors data compiled in references and specifications are influenced by the population from which they were drawn and the reason they were collected. Human factors design criteria are sometimes based on studies using few subjects or are context-specific. Ergonomics experts should be consulted where data development or interpretation is required.
3.3 The equipment design should incorporate reasonable accommodations for users with special needs, such as left- handedness and color blindness. Where feasible the design should also accommodate users with hearing or vision impairments and/or physical disabilities. It should be understood that although designing for the target user population will accommodate some users with special needs, these guidelines cannot anticipate and fully accommodate all such users.
3.4 Existing models and subsystems that meet previous versions of SEMI S8 should continue to meet the guidelines of SEMI S8 in force at the time of design. Models with redesigns that significantly affect the ergonomic design of the equipment should include conformance to the latest version of SEMI S8 for the redesign.
S10 Risk Assessment 风险评估
1 Purpose
1.1 The purpose of this Safety Guideline is to establish general principles for risk assessment to enable identification of hazards, risk estimation and risk evaluation in a consistent and practical manner. The Document provides a framework for carrying out risk assessments on equipment in the semiconductor and similar industries and is intended for use by supplier and purchaser as a reference for EHS considerations.
1.2 Use of this Safety Guideline is intended to assist in the development of a strategy to prioritize and control risks. 2 Scope
2.1 This Safety Guideline is intended to apply to the assessment of risks considering the lifecycle of the equipment.
2.2 This Safety Guideline outlines a hazard identification, risk estimation, and risk evaluation process. 3 Limitations
3.1 This Safety Guideline is not intended to be used to verify compliance with local regulatory requirements.
3.2 This Safety Guideline does not cover risk reduction, mitigation, avoidance or transfer techniques.
3.3 This Safety Guideline is not intended to explain specific risk assessment techniques, such as Fault Tree Analysis(FTA), Event Tree Analysis (ETA), Hazard and Operability Studies (HAZOP) and Failure Mode Effect Analysis(FMEA). However, it recognizes that these techniques exist and that they are adequately covered elsewhere.
S14 Fire Risk Assessment 火灾风险评估
1 Purpose
1.1 This Safety Guideline provides considerations to the manufacturers of semiconductor manufacturing equipment that will assist them in assessing and mitigating the risk to equipment and product associated with fire and combustion by-products.
1.2 Although this Safety Guideline is written in the form of an assessment tool, it is intended for use throughout the design and development of semiconductor manufacturing equipment.
1.3 This Safety Guideline may also be used by the users of such equipment and by other interested parties to assess and compare the described risks of various equipment designs or in the design and evaluation of ancillary equipment or modifications.
1.4 This Safety Guideline is not intended to specify which techniques (e.g., selection of materials or detection systems) are to be used to mitigate fire risk. These guidelines do, however, recommend that the traditional risk management hierarchy of elimination, engineering controls, administrative controls, warning and work practices be followed.
1.5 The appropriate application of this Safety Guideline will result in a report which identifies, analyzes and assesses residual fire risks. 2 Scope
2.1 This Safety Guideline applies to equipment used to manufacture, measure, assemble, and test semiconductor products which is intended to be located in clean-rooms used for semiconductor manufacturing processes or areas within their recirculation airstream. They apply to all of the components of the equipment, as described herein.
2.2 This Safety Guideline applies to fire risks originating within the subject equipment that may result in damage to it, other equipment, products, or the facility.
2.3 This Safety Guideline identifies considerations for assessing the fire risk of semiconductor manufacturing equipment, means of categorizing the risks, and means of mitigating the risks. 3 Limitations
3.1 This Safety Guideline does not establish acceptance criteria for residual risk.
3.2 This Safety Guideline recommends a hierarchy of approaches (e.g., elimination of a hazard is preferable to an engineering control) but neither prescribes which specific risk mitigation methods (e.g., change of material or elimination of an ignition source) are to be used nor ranks their relative merit.
3.3 This Safety Guideline applies to equipment in its scope when the equipment is used in the environment specified by the equipment supplier. Specifically, it does not apply to the behavior of equipment when it is subject to an external fire.
3.4 This Safety Guideline is not intended to be used to assess compliance with regulatory requirements, nor is it intended to be adopted as regulation.
3.5 Because of these limitations, it may be appropriate for purchasers of equipment to specify the applicable codes and standards and the acceptable level of residual risk.
S22 Electrical Design 电气设计安全
1 Purpose
1.1 This Safety Guideline is intended as a set of performance-based environmental, health, and safety (EHS) considerations for semiconductor manufacturing equipment. 2 Scope
2.1 Applicability — This Safety Guideline applies to equipment used to manufacture, measure, assemble, and test semiconductor products.
2.2 Precedence of Sectional Requirements — In the case of conflict between provisions in different sections of this Safety Guideline, the section or subsection specifically addressing the technical issue takes precedence over the more general section or subsection. 3 Limitations
3.1 This Safety Guideline is intended for use by supplier and user as a reference for EHS considerations. It is not intended to be used to verify compliance with local regulatory requirements.
3.2 It is not the philosophy of this Safety Guideline to provide all of the detailed EHS design criteria that may be applied to semiconductor manufacturing equipment. This Safety Guideline provides industry-specific criteria, and refers to some of the many international codes, regulations, standards, and specifications that should be considered when designing semiconductor manufacturing equipment.
3.3 This Safety Guideline is not intended to be applied retroactively.
3.3.1 Equipment models with redesigns that significantly affect the EHS aspects of the equipment should conform to the latest version of SEMI S2.
3.3.2 Models and subsystems that have been assessed to a previous version of SEMI S2 should continue to meet the previous version, or meet a more recently published version, and are not intended to be subject to the provisions of this version.
3.4 In many cases, references to standards have been incorporated into this Safety Guideline. These references do not imply applicability of the entire standards, but only of the sections referenced.
S23 Conservation of Energy 能效评估
1 Purpose
1.1 This Guide addresses concepts related to energy, utilities, and materials use efficiency of semiconductor manufacturing equipment (SME).
1.2 This Guide is intended to be a tool that can be used to analyze energy, utilities, and materials use by SME.
1.3 This Guide also addresses measurements related to energy, utilities, and materials use in SME.
1.4 This Guide also addresses continuous improvement planning for energy, utilities, and materials use in SME in order to promote efficiency.
1.5 This Guide is a series of options and instructions intended to increase awareness of the reader to available techniques in the area of energy, utilities, and materials use efficiency. A particular course of action is suggested for energy, utilities, and materials use measurement and conversion of use measurements into equivalent energy. 2 Scope
2.1 This Guide describes methods for reporting energy, utilities, and material use rate and efficiency improvement in SME.
2.2 This Guide also suggests use of energy equivalent values in order to facilitate quantification of overall energy consumption related to SME as well as planning of energy efficiency improvement.
2.3 Additionally, this Guide describes setting targets for, verifying, and improving the use or efficiency of utilities, materials, or energy.
2.4 This Guide addresses the process, idle, rest, and sleep modes of the use stage of the SME life cycle. 3 Limitations
3.1 This Guide is not intended to supersede the applicable codes and regulations of the region where the SME is used.
3.2 This Guide focuses only on the use stage of the SME life cycle and addresses a limited set of utilities and materials to be considered.
3.3 This Guide is not intended to provide definite targets for improvement on use or efficiency of utilities, materials, or energy.
3.4 The information suggested in this Guide need not be provided by the SME supplier to the user unless that is the agreement between those parties.
S30 Energetic Materials 高能材料使用
1 Purpose
1.1 This Safety Guideline is intended as a minimum set of safety criteria for the procurement, storage, handling, and use of energetic materials in semiconductor R&D and manufacturing processes in all phases of use, from process chemical supply through abatement.
1.2 This Safety Guideline is intended to be industry best practices as of its publication date. 2 Scope
2.1 The scope of this Document is energetic materials, as defined in ¶ 5.2.18 and the equipment which contains them.
2.2 This Safety Guideline specifies the testing and criteria for determining whether a material is an ‘energetic material’ in the context of this Safety Guideline.
2.3 This Safety Guideline also describes the minimum characterization data to be provided in research and development, pilot-line, or high-volume semiconductor manufacturing equipment.
2.4 This Safety Guideline provides safety design criteria for process chemical supply, process, and post-process equipment for semiconductor processes using energetic materials.
2.5 This Safety Guideline provides industry-specific criteria, and refers to some of the many international codes, regulations, standards, and specifications that should be considered when designing semiconductor manufacturing equipment. 3 Limitations
3.1 This Safety Guideline is intended for use by suppliers and users as a reference for EHS considerations. It is not intended to be used to verify compliance with regulatory requirements.
3.2 It is not the philosophy of this Safety Guideline to provide all of the EHS design criteria that may be applied to semiconductor manufacturing equipment.
3.3 This Safety Guideline was developed as a supplement, primarily addressing energetic material reaction risks, to other SEMI Standards Documents. The reader should consult those documents, including SEMI S2 and SEMI S6, for guidance for managing the safety, health, and other risks associated with energetic materials.
3.4 In some cases, references to standards have been incorporated into this Safety Guideline. These references do not imply applicability of the entire standards, but only of the sections referenced.
3.5 This Safety Guideline is not intended to apply to facilities or operations of energetic material manufacturers or distributors, or to the transportation of energetic materials beyond the boundary of any facility.
3.6 Materials within the Scope of SEMI S18 are not subject to this Document, regardless of whether they conform to the definition of ‘energetic materials’.
3.7 Aqueous process chemicals and their aqueous byproducts are not within the scope of this Document.
F47 Voltage Sag Immunity 电压暂降
1 Purpose
1.1 Semiconductor factories require high levels of power quality due to the sensitivity of equipment and process controls. Semiconductor processing equipment is especially vulnerable to voltage sags. This Specification defines the voltage sag immunity required for semiconductor processing, metrology, and automated test equipment. This Specification strikes a balance between voltage sag immunity and increased equipment cost. 2 Scope
2.1 This Specification sets minimum voltage sag immunity requirements for equipment used in the semiconductor industry. Immunity is specified in terms of voltage sag depth (in percent of nominal voltage remaining during the sag) and voltage sag duration (in cycles or seconds). This Specification also sets procurement requirements, test methods, pass/fail criteria, and test report requirements.
2.2 The primary focus of this Specification is semiconductor processing equipment including but not limited to the following types:
• Etch equipment (Dry & Wet)
• Film deposition equipment (CVD & PVD)
• Thermal equipment
• Surface prep and clean equipment
• Photolithography equipment (Scanner, Stepper & Tracks)
• Ion implant equipment
• Metrology equipment
• Automated test equipment
• Chemical mechanical polishing/planarization equipment
2.2.1 The secondary focus of this Specification is subsystems and components that are used in the construction of semiconductor processing equipment, including but not limited to:
• Power supplies
• Radio frequency generators and matching networks
• Ultrasonic generators
• Computers and communication systems
• Robots and factory interfaces
• AC contactor coils and AC relay coils
• Chillers and cryo pumps
• Pumps and blowers
• Adjustable speed drives
2.3 This Specification applies to semiconductor processing equipment to include the equipment mainframe and all subsystems whose electrical power is directly affected by the operation of the equipment’s emergency off (EMO) system.
2.4 Grandfather Clause — Equipment, subsystems, and components that were tested or certified under the previous version of this Specification, prior to the publication date of this Specification, do not require re-testing or re- certification until hardware or software design changes that could affect voltage sag immunity are implemented. 3 Limitations
3.1 Not included in this set of requirements and recommendations are over-voltage conditions (voltage swells), high frequency impulse events, and other power disturbances. If necessary, the Information Technology Industry Council (ITIC) curve contained in IEEE 1100 and SEMI E51 can be used to specify additional requirements outside the scope of this Specification.
3.2 This Specification does not address wafer quality variations that may be caused by voltage sags. It is recommended that equipment manufacturers consider the effects of voltage sags on their equipment processes. If voltage sags that are shallower and/or shorter than those in Table 1 can result in known wafer quality problems, it is recommended (but not required) that a power quality sensor coupled to a notification scheme be included in the equipment design.
3.3 This Specification addresses voltage sag immunity of semiconductor processing equipment. Voltage sag immunity of factory systems, and electric utility voltage sag performance, are covered in other related standards.
3.4 This is a performance specification. It does not address design issues related to safety, which are covered elsewhere in SEMI Standards (see SEMI S2).
3.5 Safety-related systems may require voltage sag immunity for conditions up to and including full power failure. Further, if hazards could result from voltage sags deeper and/or longer than those considered in this Specification, provision should be made to negate or eliminate such hazards.
3.6 Conflicts between this Specification and safety requirements (such as SEMI S2) that cannot be otherwise resolved shall be decided in favor of safety requirements.
3.7 This Specification does not pre-empt or override international, national, and local codes that may apply in different facility locations. Such codes, regulations, and laws should be consulted to ensure that equipment meets regulatory requirements in each location.
E78 Electrostatic Discharge (ESD) and Electrostatic Attraction (ESA) 设备静电放电(ESD)与静电吸附(ESA)评估与控制
暂无内容
Let's Talk About Safety
If you are developing, manufacturing or using semiconductor equipment, talk to us about your safety requirements.